FX1N-60MR-D MITSUBISHI PLC FX1N-60MR-D


MITSUBISHI inverter FR-A720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 3.7KW.
Inverter output for the PWM wave, containing more harmonic.
Frequency conversion power sensor through the input voltage and current signals to exchange sampling,
Sampling value through cable, optical fiber and other transmission systems and digital input frequency conversion power aanalyzer,
The sampling value of the voltage and current is calculated by the digital input frequency conversion power analyzer,
It can obtain the parameters such as voltage effective value, current effective value, fundamental wave voltage, fundamental current, harmonic voltage, harmonic current, active power, fundamental wave power and harmonic power FX1N-60MR-D FX1N-60MR-D. Analog output expansion board (1 channel) FX1N-60MR-D.
Max input / output points: 60 points.
Power supply voltage: DC24V.
Input points: 36 points.
Output points: 24 points.
Output type: relay.
Power consumption (W): 35.
Weight (kg):0.8.
Size (WxHxD) mm:175x90x75.
FX1N series is a very powerful micro PLC, can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board MITSUBISHI FX1N-60MR-D.
Communication and data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect.
A PLC unit can output 2 100KHz pulses at the same time,
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute position readout, absolute or relative drive, and special pulse output control MITSUBISHI FX1N-60MR-D. MITSUBISHI inverter FR-D720S series.
Voltage level: single phase 200V.
Frequency converter capacity: 1 MITSUBISHI FX1N-60MR-D.5KW.
VVVF frequency control, vector control frequency conversion, direct torque control is a kind of AC - DC - AC frequency conversion.
The common drawback is that the input power factor is low, the harmonic current is big, and the DC circuit needs large energy storage capacity,
Renewable energy and can not be fed back to the power grid, which can not be carried out in the four quadrant operation. To this end, the matrix type of AC - AC variable frequency arises at the historic moment.
Because the matrix type alternating current frequency saves the intermediate DC link, thereby, the electrolytic capacitor with large volume and high price can be omitted.
It can achieve a power factor of L, the input current is sinusoidal and can run in four quadrant, the power density of the sysstem is large FX1N-60MR-D.
Although the technology is not yet mature, but still attract a large number of scholars in-depth study.
In fact, the quality is not the indirect control current, flux, but the torque is directly used as the control to achieve.