Master station module for CC-Link/LT.
I/O control can be used in the province of CC-LINK/LT.
Is to make PLC CC-LINK/LT as the main station of the FX system module.
The master station module and the remote I/O module can be connected by a special connector, and achieve the purpose of the distribution of the province.
Up to 64 remote I/O station modules can be connected.
Remote I/O module is assigned a common X, Y soft components,
By using the same procedure as the common input and output
FR-BMF-22K
Even if the use of 2 points, 4 points of the remote I/O module, the number of soft components can be continuously assigned,
So it can be efficiently allocated I/O. 32: terminal line adapter 0.3mm2 (AGW22).MITSUBISHI inverter FR-A720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 0.4KW.
Inverter output for the PWM wave, containing more harmonic.
Frequency conversion power sensor through the input voltage and current signals to exchange sampling,
Sampling value through cable, optical fiber and other transmission systems and digital input frequency conversion power analyzer,
The sampling value of the voltage and current is calculated by the digital input frequency conversion power analyzer,
It can obtain the parameters such as voltage effective value, current effective value, fundamental wave voltage, fundamental current, harmonic voltage, harmonic current, active power, fundamental wave power and harmonic power. 26 point with the connection transformation adapter 16 type 1 point input CC-Link unit to install the special connection transformation adapterControl mode: loop program execution.
Input / output control mode: refresh mode.
Programming language: ladder diagram, function block.
Processing speed (CIS): 0.10 s.
Program capacity: 14k step.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down.
FR-BMF-22K Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FR-BMF-22K&select=5