Superior high efficiency IPM motor.
Output power: 1.5kw.
Rated speed: 1500r/min.
Voltage level: 200V.
IPM motor MM-EFS series can not be used to run the power frequency power.
The total wiring length of the IPM motor shall not exceed 100m.
1 inverters can not connect multiple IPM motors at the same time. Cable length 5 meters.
Extended substrate for connection.Axis of control: 1.
A1SD70 is a kind of voltage output type single axis positioning control module,
Equipped with a servo motor can form a closed loop control system of precise positioning
HA-LF601
Its fastest positioning speed up to 400Kpps, the location of the 32 bit binary number (with a symbol bit).
Positioning units according to the specific application settings, such as the number of pulses, millimeters, inches or degrees. The length of the line: 10M.
IP level: IP67.
Bending life: high bending life.
Encoder cable for 15K1M, 11K1M4, HF-JP11K1M, 15K1M4. Cable length: 3 meters.
For GOT and parallel printer connection. Output points: 32 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
16 points / a common end.
38 point terminal station.
With short circuit protection. With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
HA-LF601 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=HA-LF601&select=5