Input points: 4 points.
Weight: 0.02kg.
Function expansion board is used in the FX3SA, FX3S, FX3GA, FX3G, FX3GE on the small number of input and output extension of the product,
Can be built into PLC. MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 0.2kw.
Interface type: SSCNET type III fiber communication.
Special features: integrated driver security.
Power specification: single phase AC100V
HA-LP30K1
STO function as a security feature is added to the SSCNET III fiber communication type servo amplifier.
By using the STO function, the electromagnetic contactor used in the past to prevent the motor from accidentally starting is no longer needed.
SS1 functions can be realized by using the MR-J3-D05 security logic unit.
MR-J3-BS uses a full closed loop control system.
Compatibility with MR-J3-B.
MR-J3-BS installation, wiring and connectors are the same as the MR-J3-B, so do not change the existing connection will be easy to MR-J3-B
Change to MR-J3-BS.
Security functions are connected to the CN8 interface through an external security circuit to increase the MR-J3-BS driver security.
Compatible full closed loop control system.
MR-J3-BS has a full closed loop control system version. MITSUBISHI universal AC servo amplifier MELSERVO-JE series.
Rated output: 3.0kw.
Interface: General purpose.
Compatible motor: HG-KN302J-S100, HG-KN302BJ-S100.
MR-JE-A is equipped with a positioning function!
Be able to realize the positioning of the point set list and the way of the program.
At the same time, it also has a simple cam, encoder to follow, mark detection and other equipment can achieve high performance of the advanced functional group.
Without positioning module, the controller can build a positioning system, which can simplify the system.
Command interface using DI/O and RS-422/RS-485 serial communication (maximum 32 axis),
Can simply set the positioning data through the Configurator2 MR. Input and output points: 4096 points.
Input / output data points: 8192 points.
Program capacity: 30K.
Basic command processing speed (LD command) s:0.15.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
HA-LP30K1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=HA-LP30K1&select=5