Superior high efficiency IPM motor.
Output power: 55kw.
Rated speed: 1500r/min.
Voltage level: 400V.
IPM motor MM-EFS series can not be used to run the power frequency power.
The total wiring length of the IPM motor shall not exceed 100m.
1 inverters can not connect multiple IPM motors at the same time. The control cabinet for additional positive CF port (B disk).
Applicable models: GT16, GT15. "Analog output channel number: 4CH
HF-JP3534
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Conversion speed: 80 s/CH.
Channel to channel insulation
Output short circuit protection: have.
External power supply: DC24.
External wiring connection mode: 18 point screw terminal.
Voltage output
Digital input value: 32000 ~ 32000.
Analog output voltage: DC - 10 - 10V.
Current output
Digital input value: 0 ~ 32000.
Analog output current: DC0 ~ 20mA.
The analog output module is the interface of analog signal to the external output through the programmable controller.
Can choose voltage output, current output, voltage / current mixed output type for a variety of purposes of the module.
High speed output flow simulation waveform.
The analog output module has the function of registering arbitrary waveform data to the module, and continuously executing the analog output according to the set conversion cycle.
Execute the analog quantity (torque) control of stamping machine and injection molding machine, can automatically output the control waveform,
Through the process of high speed, smooth control. In addition, only prior to the waveform data are registered in the module,
Can easily control the analog waveform, so the production line control, such as repetitive control,
Without using a special program to create the waveform, can reduce the programming time. MELSECNET/MINI (-S3) data link system, A2C system transfer converter.
Twisted pair cable - plastic optical fiber cable.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.
HF-JP3534 Operation manual / Instructions / Catalog download link: