The output signal can open collector output inverter host standard.
Can be from the voltage output terminal (AM0), the current output terminal (AM1) output analog signal (output frequency, output current, etc.).
Can be connected to the 20mA DC or 10V DC meter. "Adapter for mounting rails. I/O unit.Cable flat cable;
Connector with 20 pin installed at both ends of the fuse.
Length 3M. Output type: transistor output, drain type
MR-J2-70C
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5mA.
External connection: 2 wire.
Type of input and output terminal.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. High performance type CPU, process CPU, memory card protection cover for redundant CPU.
Q3MEM-4MBS-SET bundled products."10BASE2.
Ethernet interface module capable of selecting the most suitable system and object device.
Support 100BASE-TX, can speed up the transmission speed. (QJ71E71-100)
Data communication can be performed between programmable controller CPU using special instructions.
Can use the HTTP protocol, through the Web browser on the PC access to the soft element of the programmable controller.
PC (Web) on the use of the communication program library and sample screen can be obtained by download services.
Can connect a number of programming tools to improve the efficiency of debugging.
Make use of e-mail function, through the mail server to send e-mail (ASCII format) and attachments (binary, ASCII and CSV format).
The KeepAlive function can be used to perform the existence of the object equipment inspection, and keep the connection in the open state.
This can be used to ensure connectivity and to quickly find errors.
Optimal network matching for application purposes and applications,
Seamless communication between different hierarchical systems.
Enhancing the ability of information communication through network.
This is also a major task in the field of automation.
Network environment provided by Q series
Is truly open & seamless.
Including based on universal ethernet,
Achieve easy management of the environment "IE Control CC-Link" controller network,
As well as in its management to achieve a high-speed, high-capacity transmission of the "IE Field CC-Link" field network.
Also including Japan''s first, to achieve the world standard,
And get the SEMI certification of the field network "CC-Link",
And inherited the design concept of the provincial distribution network CC-Link/LT".
And support sensor networks "AnyWire",
To enrich the lineup flexibility to integrate the various layers of automation network. "
MR-J2-70C Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MR-J2-70C&select=5