Input signal: thermocouple type K or type J.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V).
Thermocouple type temperature sensor input module.
Thermocouple type (K type, J type) temperature sensor input module.
4 channels can be entered.
Unit can be set to Celsius or fahrenheit.
Resolution is K type 0.4 degree, J type 0.3 degree of high precision
FX2N-CNV-BD SI-200/250 fiber optic cable.
Double loop.
MELSECNET (II) (remote I/O station).
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc.. Servo motor series: low inertia, medium and large capacity.
Rated output: 15.0kw.
Rated speed; 1000r/min.
Electromagnetic brake: No.
Power supply: 200V.
Most suitable for medium and large capacity, low inertia type products in high frequency operation or acceleration and deceleration operation.
Improve the environmental performance of HG-SR, HG-JR series of products using IP67.
High speed & high torque. Shorten the positioning time, achieve high-speed equipment.
100 scene, there are 100 different drive control.
In order to meet the needs of the diverse and detailed field,
MR-J4 product line configuration, providing a wealth of servo amplifier and servo motor products.
Can meet the different needs of different customers. Control mode: loop program execution.
Input / output control mode: refresh mode.
Programming language: ladder diagram, function block.
Processing speed (CIS): 0.10 s.
Program capacity: 14k step.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down.