Motor series: low inertia, small capacity.
Using a serial absolute / incremental encoder.
Rated output power: 0.6kw.
Rated speed: 3000rpm.
With the brake: without.
Shaft end: straight shaft.
AC servo motor and brushless DC servo motor in the function of the difference: AC servo is better, because it is a sine wave control, torque ripple small.
DC servo is a trapezoidal wave. DC servo is simple and cheap
FX3S-14MT/DSS Servo motor series: low inertia, medium and large capacity.
Rated output: 7.0kw.
Rated speed; 1500r/min.
Electromagnetic brake: incidental.
Power supply: 400V.
Most suitable for medium and large capacity, low inertia type products in high frequency operation or acceleration and deceleration operation.
Improve the environmental performance of HG-SR, HG-JR series of products using IP67.
High speed & high torque. Shorten the positioning time, achieve high-speed equipment.
100 scene, there are 100 different drive control.
In order to meet the needs of the diverse and detailed field,
MR-J4 product line configuration, providing a wealth of servo amplifier and servo motor products.
Can meet the different needs of different customers. Input and output points: 480 points.
Program capacity: 7K step.
Basic command processing speed: 4.4 ~ 5.6us.
Power supply: input DAC100 ~ 120/200 ~ 240V/ output 2A DC24V, 0.5A DC5V.
Coaxial data communication line function.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
FX3S-14MT/DSS Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FX3S-14MT/DSS&select=5