Type: HF-KE servo motor, low inertia, low power.
Rated output power: 0.75kw.
Rated speed: 3000r/min.
Electromagnetic brake: there.
Oil seal: have.
Encoder resolution: 131072p/r.
S100 representative: Super MR-E special motor.
KH003 special mark for Super MR-E.
Wide use.
Machining equipment and machine tool feed.
Used for food, packaging equipment and feeding device.
For textile machinery, etc..
Can improve the performance of equipment
FX3U-32MT/ES-A
Servo amplifier terminals are used to reduce the required wiring time.
The connector is located in front of the servo amplifier, which is convenient for cable connection.
The gain adjustment can be easily carried out by the real-time automatic tuning function.
High performance and easy to operate, reduce work load.
Enhanced system cost performance.
High performance, high precision positioning (servo motor encoder resolution: 131072).
High response.
Suppression of vibration by adaptive vibration suppression control.
Using personal computer and servo setup software to optimize tuning.
Has 2 types of interfaces:
Position control and speed control with pulse train interface.
The analog input interface is used for speed control and torque control. Input voltage range: AC100 ~ 120V/AC200 ~ 240V.
Output voltage: DC5/12V.
Output current: 2.3A/1.5A.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.