Servo motor series: medium inertia, small capacity.
Rated output: 2.0kw.
Rated speed: 1000r/min.
Electromagnetic brake: No.
Power supply: 200V.
Stable driving of medium capacity and medium inertia type products.
Through the optimization of structural design, to achieve the minimum length of the industry.
High speed & high torque. Shorten the positioning time, achieve high-speed equipment.
Reducing the electric torque ripple
HA-FF43B
Through the combination of the optimal number of the motor and the slot number, the torque ripple is greatly reduced,
To further realize the smooth constant speed device.
Improve the environmental performance of HG-SR, HG-JR series of products using IP67. Motor series: medium inertia, medium capacity.
Using a serial absolute / incremental encoder.
Rated output power: 2.0kw.
Rated speed: 1000rpm.
With the brake: without.
Shaft end: straight shaft.
The structure of the AC servo motor stator is basically similar to the capacitor split phase single-phase induction motor.
The stator is provided with two positions of 90 degrees of mutual difference of the winding, one is the excitation winding Rf, it is always connected to the AC voltage Uf;
The other is to control the winding L, which is connected to the control signal voltage Uc.
So the AC servo motor, also known as the two servo motor. Cable length: 3m.
(for MR-J2S- / CP (1) -S084).
For MR-J2S-11KA (4) MR-J2S-22KA to (4). "The most common station 11 units connected network: 121.
The 11 largest network connection units security station: 32.
Maximum network number: 239 sets.
Maximum secure connection of 1 units: 31 connection.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down. "