Analog output channel number: 16CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C:-.
Temperature coefficient: positive and negative 50ppm/.
Conversion speed: 1ms/CH.
Insulation between channels: isolation transformer insulation.
Output short circuit protection: have.
External power supply: -.
External wiring connection: 40 pin connector two
HC-SFS52G2 1/5
Voltage output
Digital input value: 32000 ~ 32000.
Analog output voltage: DC - 10 - 10V.
Current output
Digital input value: 0 ~ 32000.
Analog output current: DC0 ~ 20mA.
Without using a special program to create the waveform, can reduce the programming time.
Easy to use parameters to set the conversion operation and scaling, no need to create a dedicated program.
Therefore, it is helpful to reduce the development cost of the program and to reduce the program capacity.
High speed output flow simulation waveform.
The analog output module has the function of registering arbitrary waveform data to the module, and continuously executing the analog output according to the set conversion cycle.
Execute the analog quantity (torque) control of stamping machine and injection molding machine, can automatically output the control waveform,
Through the process of high speed, smooth control. In addition, only prior to the waveform data are registered in the module,
Can easily control the analog waveform, so the production line control, such as repetitive control,Ethernet network module 10BASE-T / 10BASE5.The connector is converted to a screw relay terminal.Connecting cable for handheld GOT and PLC.
Cable length: 1.5 meters.
Application: RS-232C connection (Q series (except for QnU). E81WH4W, QE83WH4W special transformer.
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information.
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products.
For example, a module can be used to measure other loads from the control panel trunk.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.
HC-SFS52G2 1/5 Operation manual / Instructions / Catalog download link: