Input type: DC input, positive common end.
Input points: 32 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 3 wire.
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Input and output (DC/ differential)
HG-SN102J-S100
Input points: 12 points (DC5V/DC24V/ differential universal).
Pulse input speed: the highest pulse/s 8M (2MHz).
Output points: 8 points (DC5V ~ DC24V) 6 points (differential).
Pulse output speed: the highest pulse/s 8M (2MHz).
High speed and stable input / output response
The high speed response can be achieved without the CPU module''s operation and bus performance,
Stable input and output response through hardware processing.
LD40PD01 is equipped with an external input and output interface and FPGA,
Therefore, high speed control can be realized without the influence of the scanning time of the CPU module and the bus performance (the input and output response time of the s instruction is realized).
Can achieve stable input and output response (processing time of the deviation of the ns level).
Through the intuitive tools for FPGA settings.
In the FPGA design process can be omitted in the past must be designed to deal with (HDL description, logic synthesis and time verification),
Reduce working hours. After receiving the product can be used immediately to verify the use of special tools, can significantly shorten the design time. Capacity: 1MB.MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 355kw.
SLD converter rated current: 770A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON.
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the corresponding signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation.
Can reduce the power consumption in the stop.
HG-SN102J-S100 Operation manual / Instructions / Catalog download link: