Motor series: low inertia, medium capacity.
Rated output power: 6.0kw.
Rated speed: 1000rpm.
With the brake: without.
Shaft end: straight shaft.
The rotor of the servo motor is a permanent magnet, which is controlled by the U/V/W,
The rotor rotates under the action of the magnetic field, and the encoder feedback signal of the motor is given to the driver,
According to the feedback value and the target value, the driver adjusts the rotation angle of the rotor
MR-H3CBL1M
Accuracy of the servo motor depends on the accuracy of the encoder (number of lines). Motor series: low inertia, low power.
Rated output power: 0.2kw.
Rated speed: 3000r/min.
Whether with brake: No.
Shaft end: key shaft (open slot).
Protection level: IP55 does not include the shaft part and the connector.
Features: low inertia is particularly suitable for high speed motor (6000 or 12000 RPM / min) of general industrial machinery.
Application example 1: drive belt drive, robot.
Application example 2: assembly machine, sewing machine, X-Y working table.
Application example 3: food manufacturing machinery, semiconductor manufacturing equipment, knitting machine and embroidery machine.
High resolution encoder 131072p/rev (17 bit).
The encoder with high resolution ensures excellent performance and stability at low speed.
All motor dimensions are the same as before and all are compatible with the wiring. MELSECNET/10.
Inter-PC coaxial bus. Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive and negative sharing.
Output points: 16 points.
Output voltage: DC24V/AC240V, 2A/1 point, 4A/ common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side.
50 point terminal station.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.