Type: HA-FE series.
Rated output: 0.1KW.
Rated speed: 3000r/min.
Electromagnetic brake: there.
Control complex, easy to achieve intelligent,
The electronic commutation method is flexible and can be changed by square wave or sine wave.
Motor maintenance free, high efficiency, low operating temperature,
Electromagnetic radiation is very small, long life, can be used in a variety of environments.
AC servo motor is brushless motor, which is divided into synchronous and asynchronous motor,
Synchronous machines are commonly used in motion control,
Its power range, you can do a lot of power
MR-J2S-30KB
Large inertia, the maximum rotation speed is low, and with the increase of power and rapid reduction.
So it is suitable for the application of low speed and stable operation.
The rotor of the servo motor is permanent magnet,
Drive controlled U/V/W three phase electric electromagnetic field,
The rotor rotates under the action of the magnetic field,
At the same time the motor comes with the encoder feedback signal to the drive,
According to the feedback value and the target value, the driver is compared,
Adjust the rotor rotation angle.
The accuracy of the servo motor is determined by the accuracy of the encoder. 2 slots.
Can be installed in the power supply unit for A series units installed QnA/.
Cannot extend.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate.
MR-J2S-30KB Operation manual / Instructions / Catalog download link: