MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 0.6kw.
Interface type: CC-Link communication type (built-in positioning function).
Power specification: single phase AC200V.
Positioning operation by setting position and rotational speed data in the positioning table and receiving the start signal from the main controller.
The setting of the position and speed of the positioning table, as well as the start and stop operation can be completed through CC-Link communication
Q170BAT
By using the MR-J3-D01 extension IO unit, the DI/O instruction can be used to select and locate the table.
(CC-Link can not be used for MR-J3-D01 communications).
With built-in positioning function of the servo amplifier, can be set through the CC-Link communications and speed data. (corresponding to the CC-Link version: Ver.1.10)
Can be achieved through the CC-Link communications to start, stop and monitoring and other operations.
Serial communication reduce wiring.
Distributed servo control system can be built by CC-Link communication.
The parameters of unit MR-PRU03 (optional) the parameter setting, operation and monitoring more convenient.
The servo amplifier can be used for speed control operation.
When the two stations are occupied, the speed can be set directly by the remote register. Connector set for
HC-SFS121B; 201B; 301B.
HC-SFS202B; 352B; 502B; 702B; 2024B; 5024B; 3524B; 7024B.
353B; HC-SFS203B.
302B; HC-LFS202B.
HA-LFS601B; 801B; 12K1B; 6014B; 8014B; 12K14B.
HA-LFS701MB; 11K1MB; 15K1MB; 701M4B; 11K1M4B; 15K1M4B.
15K2B; HA-LFS11K2B. Capacity: 32M bytes.
Better user experience data recording function.
Easy to record, no need to program.
Simply through the special configuration tool wizard to easily complete the settings,
The collected data can be saved in CSV format to SD storage card.
Can be effectively used to save the CSV file to facilitate the creation of a variety of reference materials,
Including daily reports, generate reports and general reports.
These data can be applied to the data analysis, tracing, etc..
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording.
Even when remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording.
Q170BAT Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=Q170BAT&select=5