Function: 4CH voltage / current output.
Adapter for connecting the left extension function of the CPU module.
CPU module can be connected to the left side up to 6 units. MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 30KW.
Frequency converter common frequency of a given way: the operator keyboard is given, the contact signal given, analog signal given, the pulse signal given and communication methods given, etc
Q2M2M-16MBA.
These frequencies have their advantages and disadvantages, and should be selected according to the actual needs.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions. Servo motor series: low inertia, medium and large capacity.
Rated output: 25.0kw.
Rated speed; 1000r/min.
Electromagnetic brake: No.
Power supply: 400V.
Most suitable for medium and large capacity, low inertia type products in high frequency operation or acceleration and deceleration operation.
Improve the environmental performance of HG-SR, HG-JR series of products using IP67.
High speed & high torque. Shorten the positioning time, achieve high-speed equipment.
100 scene, there are 100 different drive control.
In order to meet the needs of the diverse and detailed field,
MR-J4 product line configuration, providing a wealth of servo amplifier and servo motor products.
Can meet the different needs of different customers. Input and output points: 512 points.
Input / output data points: 512 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.20.
Optical data communication line.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Q2M2M-16MBA Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=Q2M2M-16MBA&select=5