If can use: closed loop vector control; spindle positioning, position control, speed control, servo lock zero.
Suitable frequency converter: FR-A700. Function: input / output module (internal service power supply).
Input / output points: 32 points
Input points: 16 points.
Output points: 16 points.
DC5V internal consumption current: 965mA.
DC24V internal consumption current: 250mA.
Input / output mode: DC input (drain / source) / relay output
Q6HLD-R2
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. Type of input: DC leakage.
Input points: 64 points.
Input voltage: 12/DC24.
Input current: 2/5mA.
Connection mode: terminal row.
Common common point: 32.
Functional block diagram language is a kind of PLC programming language, which is similar to digital logic circuit.
The function module is used to represent the function of the module,
Different function modules have different functions.
Functional module figure programming language features: functional block diagram programming language is characterized by a functional module for the unit,
Analysis and understanding of the control scheme is simple and easy: function module is to use graphical form of expression,
Intuitive, for a digital logic circuit based on the design of the staff is very easy to master the programming;
Control system with complex scale and complex control logic,
Because the function module diagram can clearly express the function relation, the programming debugging time is greatly reduced. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 18.5kw.
SLD converter rated current: 38.0A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control.
Q6HLD-R2 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=Q6HLD-R2&select=5