Operation control mode: stored procedure repeated operation.
Input / output points: 4096 points.
Program capacity: 320K.
As the core of the programmable controller control system, programmable controller CPU module has been equipped with a variety of functions,
Support multiple controls. Program capacity from the 40K step to the 1200K step, to select the most suitable system size of the CPU module
QJ71AS92
And the CPU module can be directly connected to the industrial network, which can reduce the construction cost of the system.
Standard interface.
The programmable controller CPU module has standard Ethernet port, USB port, SD card slot.
Ethernet port and USB port can be used to communicate with the corresponding peripheral devices,
SD memory card slot can be used to record data, databases and other data storage.
In addition, the expansion of the SRAM card can be used for the expansion of the capacity of the soft element / tag memory and used as a hardware security key. The A1SP60 pulse capture module is a 16 point DC24V input module,
Can be used as a general input module,
Can also be used as a pulse capture module,
Pulse capture function makes the input signal width in the sequence can be as short as 0.5ms,
Once there is a pulse signal input, the state is memory,
A1SP60 to ensure that the control process at least once again to control the state of the memory of the operation,
Input can be set to 4 blocks,
Each block can be set to a general function or pulse capture function. Total points: 14 points.
Input points: 8 points.
Output points: 6 points.
Voltage: AC220V.
Output type: relay.
Outline dimension: 90*75*90.
FX1N series is a very powerful micro PLC,
Can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board.
Communication and data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 3.7KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load.