A1SJ71LR21 Network module

MITSUBISHI A1SJ71LR21 Manual And Instructions
A1SJ71LR21 datasheetPDF datasheet
A1SJ71LR21 Reference Manual
A1SJ71LR21 PLC to PLC networkReference Manual
A1SJ71LR21 Reference Manual
A1SJ71LR21 HardwareUser's Manual
A1SJ71LR21 Reference Manual

MITSUBISHI A1SJ71LR21 Product information and technical parameters:
Brand: MITSUBISHI
Name: Network module
Model: A1SJ71LR21
3C-2V/5C-2V coaxial cable between double loop PC (control station / common station) / remote I/O network (remote master station).
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
This phenomenon is called the I/O delay time effect.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.

Output type: relay.
Output points: 8 points.
Load voltage: AC240/DC24.
Load current: 2A.
Connection mode: terminal row.
Common public end points: 1.
Structured text language is a programming language that describes a program with a structured description of the text.
It is a programming language similar to a high level language A1SJ71LR21. In large and medium
Structured text is often used to describe the relationship between the various variables in the control system based on the PLC system A1SJ71LR21
Mainly used for other programming languages more difficult to achieve the user program.
The structured text programming language uses the computer description method to describe the various kinds of relations between the various variables in the system,
Complete the required function or operation A1SJ71LR21.
Most PLC manufacturers use structured text programming language similar to BASIC language, PASCAL language or C language and other advanced languages,
But in order to be convenient, the expression methods of the statement and the types of statements are simplified.
Structured text programming language features: the use of high-level language programming, you can complete the complex control operations,
Need to have a certain level of computer knowledge and programming skills,
Higher requirements for engineering designers A1SJ71LR21. Poor visibility and operability. SRAM+E2PROM memory card.
RAM capacity: 256KB.
E2PROM capacity: 256KB. JEMANET (OPCN-1) interface unit from the station.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
This phennomenon is called the I/O delay time effect A1SJ71LR21.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CCPU A1SJ71LR21.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive.