A6RCON-R75 Melsecnet module


MITSUBISHI A6RCON-R75 Product information and technical parameters:
Brand: MITSUBISHI
Name: Melsecnet module
Model: A6RCON-R75
MELSECNET/10, MELSECNET/H coaxial, input voltage: AC100-240V.

There are many A6TB models to different types of matching with the I/O module.
The cable can be connected to the I/O module of 32 points or 64 points by using the terminal row of the wire in advance.
These cables have a variety of lengths to be selected, so that
Using the module wiring and terminal is not only connected with the connector A6RCON-R75. Category: Master station.
Transfer speed: 125kbps/250kbps/500kbps/1Mbps A6RCON-R75
Transmission line form: bus system.
Total distance: 125kbps:1000m/250kbps:800m/500kbps:480m/1Mbps:240m.
The maximum connection units: 32.
Total points: input + output <=2048 point.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add A6RCON-R75.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations. 8 slots.
To install the power supply.
For Q4AR power duplex.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order A6RCON-R75.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized ooutput mode A6RCON-R75.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation A6RCON-R75.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.