MITSUBISHI
Home >> Products >> MITSUBISHI >> A/QnA series PLC >> High function module >> Other high function modules >> A70BDE-J71QLP23GE Communication module

A70BDE-J71QLP23GE Communication module

MITSUBISHI A70BDE-J71QLP23GE Manual And Instructions
A70BDE-J71QLP23GE For SW3DNF-MNET10User's Manual

MITSUBISHI A70BDE-J71QLP23GE Product information and technical parameters:
Brand: MITSUBISHI
Name: Communication module
Model: A70BDE-J71QLP23GE

26 point with the connection transformation adapter 16 type 1 point input CC-Link unit to install the special connection transformation adapterInput points: 32 points.
Input voltage and current: 240V ~ 10mA AC100.
Input response time: 35ms.
16 point /1 a public side.
Output points: 24 points.
Output voltage: AC100 ~ 240V A70BDE-J71QLP23GE.
OFF leakage current: 3mA.
Output response time: 0.5Hz+1ms A70BDE-J71QLP23GE
Output type: bidirectional thyristor output.
8 point /1 a public side.
36 point terminal station.
With short circuit protection.
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A70BDE-J71QLP23GE.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian A70BDE-J71QLP23GE.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission deevice, brake signal and fan fault signal A70BDE-J71QLP23GE.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A70BDE-J71QLP23GE.


...More relevant models >>>>