MITSUBISHI
Home >> Products >> MITSUBISHI >> CC-Link module >> Remote I/O module >> AJ65VBTCE3-16DE Sensor connector type input module

AJ65VBTCE3-16DE Sensor connector type input module

MITSUBISHI AJ65VBTCE3-16DE Manual And Instructions
AJ65VBTCE3-16DE datasheetPDF datasheet

MITSUBISHI AJ65VBTCE3-16DE Product information and technical parameters:
Brand: MITSUBISHI
Name: Sensor connector type input module
Model: AJ65VBTCE3-16DE
Input type: DC input, negative public end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 3 wire.
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input.

Output type: transistor output, drain type.
Output points: 32 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup AJ65VBTCE3-16DE.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AJ65VBTCE3-16DE Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA AJ65VBTCE3-16DE.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DC24V/0.1A.
External connection: 1 line /1 line type.
Fast connector type.
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program AJ65VBTCE3-16DE.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. A pack of 10.
Applicable models:
AJ65VBTS - - - type.
AJ65VBTCE - - - type.
AJ65VBTCU - - - type.
AJ65ABTP - - - type.
AJ65VBCU- - type.
AJ65SBT-CLB type.
Can only use FANC-110SBH, CS-110, FA-CBL200PSBH. Points: 32 points
.
Rated voltage: DC24V.
Connection type: connector
.
Three remote components can be connected to the CC-LINK system.
Remote I/O: refers to those who require only the ON/OFF control function of the field components, such as digital I/O or pneumatic valve, etc..
In this type of communication can only be carried out in the bit data.
Remote components: refers to those that require processing of the register data of the field components, such as analog I/O and counters, etc AJ65VBTCE3-16DE. .
In this type of component, in addition to the bit data can be carried out in the register data communication.
Intelligent remote: this type of component is to allow the main sstation or other stations to access the action, to collect data and control the local PLC station,
GOTS and programmer interface unit are of this type AJ65VBTCE3-16DE.


...More relevant models >>>>