CL1XY2-DT1D5S Cable type input and output module

MITSUBISHI CL1XY2-DT1D5S Manual And Instructions
CL1XY2-DT1D5S datasheetPDF datasheet
CL1XY2-DT1D5S User's Manual

MITSUBISHI CL1XY2-DT1D5S Product information and technical parameters:
Brand: MITSUBISHI
Name: Cable type input and output module
Model: CL1XY2-DT1D5S
Input type: DC input, positive common end.
Input points: 1 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/4mA.
Output form: transistor output, leakage type.
Output points: 1 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0.1A.
External connection: 3 line /2 line type.
Cable type.
Minimum size of industry.
Can be like a cable, placed in the online slot.
The communication cable and the external equipment connecting cable is a type, and the wiring is simple.
Communication side, input and output side with cable (50cm).

Pulse input: differential input.
Default input: DC input.
Count range: 0~16777215.
Number of stations: 4 stops.
Station type: remote equipment station.
Configuration of master / local station,
In addition to the other site network with different CC-Link in addition to the main station and the remote station configuration can also be the main station and the local station configuration CL1XY2-DT1D5S CL1XY2-DT1D5S
A local PLC can communicate with the master station PLC and other remote workstations.
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram CL1XY2-DT1D5S.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced.
MITSUBISHI PLC online debugging CL1XY2-DT1D5S.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjust.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on step by step.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be. Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 3 line /2 line type.
Spring clip terminnal CL1XY2-DT1D5S.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module CL1XY2-DT1D5S.
When installing the module can choose to use the DIN guide rail or screw mounting.
Can be used for the 3 wire sensor input wiring.


...More relevant models >>>>