MITSUBISHI
Home >> Products >> MITSUBISHI >> CC-Link module >> CC-link spare parts >> CL2AD4-B Screw terminal table type analog quantity input module

CL2AD4-B Screw terminal table type analog quantity input module

MITSUBISHI CL2AD4-B Manual And Instructions
CL2AD4-B datasheetPDF datasheet

MITSUBISHI CL2AD4-B Product information and technical parameters:
Brand: MITSUBISHI
Name: Screw terminal table type analog quantity input module
Model: CL2AD4-B
Support Ver.2 CC-LINK. "

Input type: DC input, positive common end.
Input points: 16 points.
Input response time: 0.5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA.
External connection: 3 wire.
Sensor connection type.
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting CL2AD4-B.
3 wire sensor input. A pack of 20.
Applicable models:
AJ65SBTC - - - type remote I/O module CL2AD4-B
AJ65VBTCU - - - type remote I/O module.
AJ65VBTCU- - type remote I/O module. Enter 8 points: 24VDC.
4 wire type.
Response time: 1.5ms.
Output 8 points: 24VDC.
Transistor output.
Waterproof connector type.
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction CL2AD4-B.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced CL2AD4-B.
MITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjust.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on step by step.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be. Description: can form up to 8 star wiring, and suitable for transmission speed of the length of the line distribution, spring clip terminal type.
Spare 5 products for different purposes.
Thin waterproof type relay hub.
Extension of star type wiring and main line length, waterproof struucture CL2AD4-B.
Spring clip terminal type relay hub.
Star type wiring, length of the main line, spring clamping terminal table type.
Relay appliance (T branch) unit.
Extension of T type branch and trunk length.
Relay unit in light.
In the presence of interference in the environment of the wiring, the length of the trunk line CL2AD4-B.
Relay unit in space light.
Communication between linear moving bodies.