FA-TH16YSR21S Terminal module

MITSUBISHI FA-TH16YSR21S Manual And Instructions
FA-TH16YSR21S datasheetPDF datasheet

MITSUBISHI FA-TH16YSR21S Product information and technical parameters:
Brand: MITSUBISHI
Name: Terminal module
Model: FA-TH16YSR21S
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.

Convert connectors to e-CON.AnyWireASLINK master station.
Transmission distance: the longest 200m.
Data input and output: up to 512 points.
Connect up to 128 units.
Enter 256 points, 256 points out of the output.
Connecting the input and output of the sensor to the programmable controller.
Ultra small sensor can be freely configured to control the input and output of 512 points FA-TH16YSR21S.
In addition, the sensor can be supplied with a AnyWireASLINK transmission line (2 lines) by means of communication,
So as to facilitate additional sensor FA-TH16YSR21S
And can also be through the engineering software Works2 GX batch management sensor disconnection detection and from the station module settings, etc.,
Can significantly reduce the engineering hours FA-TH16YSR21S.
Basic composition.
AnyWireASLINKAnyWireASLINK can be selected according to the load current of 2 wire or 4 wire from the station module.
In addition to the 2 wire type, the local power supply can be connected with the 4 wire type mixed use.
2 wire type.
The load current is less than that of the hour, by using the non isolated 2 wire type from the station module,
Easy connection without using local power supply FA-TH16YSR21S.
4 wire type
By using isolated 4 wire type from the station module, the local power supply can be used,
Can support the use of more current load. Convert connector to screw relay terminal.
The action of the signal of the conversion module is shown in the light of the lamp.
Negative common end with display. IE Field CC-Link intelligent equipment station.
Transmission speed: 1Gbps.
Remote input / output: 2048 points.
Remote register: 1024 words.
RAS function.
End cap.
Play the role of IE CC-Link field network remote station
Can be installed in the IE CC-Link field network host module L series of a variety of I/O module, intelligent function module.
Can be used as the remote station of IE CC-Link field network,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space.
Management of abnormal information through the RAS function
An erroor occurred in the remote station,
After the error record is saved to the IE CC-Link field network host module''s latch area,
Instantaneous notification to the master station via the network FA-TH16YSR21S.
Even if the power of the system is cut off,, the error record in the locked area is still retained,
So it is easy to determine the location of the problem, to maximize the reduction of downtime FA-TH16YSR21S.