MITSUBISHI
Home >> Products >> MITSUBISHI >> Inverter >> FR-A800 series inverter >> FR-A840 inverter 3 phase 400V >> FR-A846-00930-2-60 IP55 converter built-in DC reactor

FR-A846-00930-2-60 IP55 converter built-in DC reactor

MITSUBISHI FR-A846-00930-2-60 Manual And Instructions
FR-A846-00930-2-60 datasheetPDF datasheet
FR-A846-00930-2-60 PLC FUNCTIONProgramming Manual
FR-A846-00930-2-60 DETAILEDInstruction manual

MITSUBISHI FR-A846-00930-2-60 Product information and technical parameters:
Brand: MITSUBISHI
Name: IP55 converter built-in DC reactor
Model: FR-A846-00930-2-60
"MITSUBISHI inverter series: FR-A846.
Voltage level: three phase 400V.
Power: 37kw.
SLD converter rated current: 93A.
Structure and function: IP55 counterpart.
Type: CA.
Substrate coating: have.
Built in DC reactor.
Easy to operate, simple settings.
We have prepared a series of equipment and functions for you to work in any place to meet the life cycle of the product.
Allegedly, the motor power consumption accounted for about half of the total power generated by manufacturing industry consumption.
How to achieve energy efficiency in the plant without affecting the productivity.
Less energy consumption and more output FR-A800 series inverter will help you to have both fish and bear''s paw"
Parameters and frequency settings can be modified in the program.
Inverter control, for example, by the input signal to trigger the operation of the inverter, based on the operation of the inverter
The status of the signal output, as well as the monitor output and so on, can be customized according to the requirements.
The control of each machine can be done separately by the frequency converter, and the control of the dispersion is also carried out.
Through combining with the real-time clock function can realize the automatic operation (in option FR-LU08). "

Length: 30 meters.
Cable manufacturing specifications.
When there is no connection options, according to the table under the cable.
Using a parallel connection or a large size cable for connection between the terminal PG" and "SD" and the motor end encoder. "Power: 37kw.
Voltage: 200V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control FR-A846-00930-2-60 FR-A846-00930-2-60
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving FR-A846-00930-2-60. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 11KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) FR-A846-00930-2-60.
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load. Power: 55kw.
Voltage: 400V.
There are 100% braking torque output in ccontinuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control FR-A846-00930-2-60.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space annd reduce the comprehensive cost FR-A846-00930-2-60.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving.


...More relevant models >>>>