MITSUBISHI
Home >> Products >> MITSUBISHI >> Inverter >> FR-F700 series inverter >> FR-F720 inverter 3 phase 200V >> FR-F720-S110K 3 phase 200V converter

FR-F720-S110K 3 phase 200V converter

MITSUBISHI FR-F720-S110K Manual And Instructions
FR-F720-S110K datasheetPDF datasheet
FR-F720-S110K AppliedInstruction manual
FR-F720-S110K BASICInstruction manual
FR-F720-S110K TECHNICAL MANUAL

MITSUBISHI FR-F720-S110K Product information and technical parameters:
Brand: MITSUBISHI
Name: 3 phase 200V converter
Model: FR-F720-S110K
MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 110KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes.
For the requirements of relatively high precision, even if the load changes are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection).
If the given acceleration time is too short, the output frequency of the inverter is far more than the change of the speed (electric angular frequency),
Converter will be due to flow over the current trip, the operation stopped, which is called stall.

Power: 45kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor FR-F720-S110K. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor FR-F720-S110K
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 18.5KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) FR-F720-S110K.
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical FR-F720-S110K.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load. Power: 280kw.
Voltage: 200V.
Sine wave filter.
The voltage and current of the motor can be adjusted to a sine wave.
The sine wave filter is installed to the output terminal of the inverter.
Applicable to FR-A820-03800 (75K) above and FR-A840-02160 (75K) and above frequency converter.
Sine wave filter is equivalent to the operational characteristics of the sine wave power driver, can provide the following benefits.
Low noise.
No surge current.
Reduce motor loss (standard motor). Power: 22kw.
Voltage: 200V.
There are 100% braking torque outputt in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control FR-F720-S110K.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space annd reduce the comprehensive cost FR-F720-S110K.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving.


...More relevant models >>>>