MITSUBISHI
Home >> Products >> MITSUBISHI >> Inverter >> FR-F700P series inverter >> FR-F740P-75K-CHT 3 phase 400V converter

FR-F740P-75K-CHT 3 phase 400V converter

MITSUBISHI FR-F740P-75K-CHT Manual And Instructions
FR-F740P-75K-CHT datasheetPDF datasheet
FR-F740P-75K-CHT BASICInstruction manual
FR-F740P-75K-CHT AppliedInstruction manual

MITSUBISHI FR-F740P-75K-CHT Product information and technical parameters:
Brand: MITSUBISHI
Name: 3 phase 400V converter
Model: FR-F740P-75K-CHT
"MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 75KW.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter. "

MITSUBISHI inverter FR-D720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 5.5KW.
Vector control variable frequency speed control is the practice of the asynchronous motor in the three-phase coordinate system of the stator current Ia, Ib, Ic, through the three-phase to two-phase transformation,
The alternating current of Ia1Ib1 is equivalent to a two phase stationary coordinate system, and then is rotated by the rotor field oriented,
Equivalent to the DC current Im1, It1 (Im1 equivalent to DC motor excitation current in synchronous rotating coordinate system;
It1 equal to the armature current proportional to the torque, and then imitate the DC motor control method, to obtain the DC motor control,
The control of asynchronous motor is realized through the corresponding inverse coordinate transformation FR-F740P-75K-CHT FR-F740P-75K-CHT FR-F740P-75K-CHT Used to reduce radio noise.MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 7.5KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) FR-F740P-75K-CHT.
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement funcction, the starting torque is more than 100%, which can start with full load FR-F740P-75K-CHT. Superior high efficiency IPM motor.
Output power: 55kw.
Rated speed: 1500r/min.
Voltage level: 400V.
IPM motor MM-EFS series can not be used to run the poower frequency power FR-F740P-75K-CHT.
The total wiring length of the IPM motor shall not exceed 100m.
1 inverters can not connect multiple IPM motors at the same time.


...More relevant models >>>>