MITSUBISHI
Home >> Products >> MITSUBISHI >> FX series PLC >> FX all modules and accessories >> FX all accessories >> FX-EEPROM-8 Memory card

FX-EEPROM-8 Memory card


MITSUBISHI FX-EEPROM-8 Product information and technical parameters:
Brand: MITSUBISHI
Name: Memory card
Model: FX-EEPROM-8
Memory format: EEPROM.
Number of steps: up to 8000 steps can be used.
Battery support: do not.
Method for writing and deleting: the device is installed on the PLC, and is written and deleted by the peripheral device.

Max input / output points: 32 points.
Power supply voltage: 24VDC.
Input points: 16 points.
Output points: 16 points.
Output type: relay.
Power consumption: 25W.
Weight (kg):0.65.
Size (WxHxD) mm:150x90x87.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time FX-EEPROM-8 FX-EEPROM-8
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications FX-EEPROM-8.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K FX-EEPROM-8.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable. Input / output form: relay output.
Output points: 16 points.
DC5V internal consumpption current: 100mA FX-EEPROM-8.
DC24V internal consumption current: 125mA.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion modulee: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points FX-EEPROM-8.