L60ADVL8-CM Analog input module

MITSUBISHI L60ADVL8-CM Manual And Instructions
L60ADVL8-CM datasheetPDF datasheet

MITSUBISHI L60ADVL8-CM Product information and technical parameters:
Brand: MITSUBISHI
Name: Analog input module
Model: L60ADVL8-CM
Number of input channels: 8ch.
Input voltage: DC - 10 ~ 10V.
Conversion speed: 1ms/ch.
Resolution: 1/16000.
By shifting the function easily when the system starts to fine tune the movement function.
Shift the set value to (shift to) the function of the digital output value.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup.
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal detection function of the input signal which is outside the range of the set range.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter range extension
Range of scalable input range.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected.

The connector is converted to a screw relay terminal.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Output points: 16 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.5A/1 point.
Protection function: have L60ADVL8-CM.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points) L60ADVL8-CM
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch L60ADVL8-CM.
Communication protocol is a standard Modbus protocol or custom protocol. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Differential output.
Axis of control: 2.
Maximum output pulse: pulse/s 4M L60ADVL8-CM.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start.
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, bit 8CH data can be displayed inn real time L60ADVL8-CM.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check.
Can only choose the necessary items from the rich monitoring information and monitor the display.
TThrough the test function, do not have to control procedures can also be implemented to confirm the basic action L60ADVL8-CM. Can be used as a screw relay terminal.