MITSUBISHI
Home >> Products >> MITSUBISHI >> CC-LINK IE network >> NZ2GF2B1-16D Modular remote DC input module

NZ2GF2B1-16D Modular remote DC input module

MITSUBISHI NZ2GF2B1-16D Manual And Instructions
NZ2GF2B1-16D datasheetPDF datasheet

MITSUBISHI NZ2GF2B1-16D Product information and technical parameters:
Brand: MITSUBISHI
Name: Modular remote DC input module
Model: NZ2GF2B1-16D
Type: 18 point terminal.
Input points: 16 points.
Rated voltage: DC24V.
Input response time: 0 ~ 70ms.
Input format: common terminal / negative public end sharing.
External connection: 1 wire.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station.

Type: 18 point terminal.
Input / output form: analog voltage and current input.
Number of channels: 4 channels.
No need to extend or change the network wiring to increase the number of analog points.
The conversion speed of the analog input module can be selected from 100 mu s/ channel, 400 mu s/ channel and 1ms/ channel NZ2GF2B1-16D. (switching speed switching function)
The conversion speed of the analog output module is 100 mu s/ channel NZ2GF2B1-16D
Can be connected to the analog input / output module (NZ2GF2BN-60AD4, NZ2GF2BN-60DA4) after the use of.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points NZ2GF2B1-16D.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station. Type: 18 point terminal.
Input type: DC input, the common cathode / negative public end sharing NZ2GF2B1-16D.
Input points: 16 points.
Rated input voltage / current: DC24V (4mA).
External connection: 1 wire.
IE CC-Link field network module type remote unit.
Select input response time from 0ms/0.2ms/1ms/1.5ms/5ms/10ms/20ms/70ms.
High speed input and output control of single module can be realized by using first order logic function.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station. Ethernet device connection, 100Mbps/1Gbps.
IE CC-Link field network EEthernet adapter module NZ2GF2B1-16D.
Ethernet devices that support seamless information protocol (SLMP) can be connected to the IE CC-Link field network.
Can effectively use the visual sensors and RFID and other rich variety of Ethernet devices.
Weeb browser can be used to set the station number, set the Ethernet options and view the error history NZ2GF2B1-16D.
Support the transmission speed of 100Mbps/1Gbps.


...More relevant models >>>>