MITSUBISHI
Home >> Products >> MITSUBISHI >> Q series PLC >> High speed counting module >> QD63P6 Multi channel high speed counter module

QD63P6 Multi channel high speed counter module

MITSUBISHI QD63P6 Manual And Instructions
QD63P6 datasheetPDF datasheet
QD63P6 User's Manual
QD63P6 HardwareUser's Manual

MITSUBISHI QD63P6 Product information and technical parameters:
Brand: MITSUBISHI
Name: Multi channel high speed counter module
Model: QD63P6
Input: 6 channels.
200/100/10kpps.
Counter input signal: 5VDC.
40 pin connector.
Support high resolution devices. Pulse input and high speed counter module product group satisfying high speed and high precision control application.
High speed counter module for counting high-speed pulse train.
Can be used in combination with the external encoder for positioning and other control.
The maximum count rate can be switched, and the low frequency pulse is counted from the high speed pulse to the rising edge / falling edge.
Each 1 channel is equipped with 2 points of external uniform output.
Can be selected according to the use of "consistent output function", "continuous comparison function", to achieve high-speed control of external equipment. (QD64D2)
Provides a variety of functions, such as the same output test function (using a continuous comparison function), the default function, the latch counter function,
In order to meet the needs of various applications. (QD64D2)
The maximum count rate of the input pulse can be up to 8Mpps (differential input, 2 phase, 4 double frequency).
Can be in the semiconductor, liquid crystal manufacturing and other high position accuracy requirements of the equipment,
Perform accurate position tracking using high resolution encoders. (QD65PD2)

4 axes, open collector output type.
Control unit: pulse.
Location data: 10 data / axis.
Maximum pulse output: 200Kpps.
40 pin connector.
Ideal solution for simple multi axis positioning.
Perfect match with stepper motor control.
Plus deceleration smooth, speed change subtle.
To speed up the speed of positioning control to start processing QD63P6.
Positioning module.
Open collector output.
Differential driver output QD63P6
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control QD63P6.
(the command pulse of the open collector positioning module is highest 200kpps.)
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance QD63P6.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown. Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion mollding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling QD63P6.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrrol (heating and cooling) mode QD63P6.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.