MITSUBISHI
Home >> Products >> MITSUBISHI >> QS safety series >> QS001CPU Secure CPU module

QS001CPU Secure CPU module

MITSUBISHI QS001CPU Manual And Instructions
QS001CPU datasheetPDF datasheet
QS001CPU Special InstructionsStrctured Programming Manual
QS001CPU Application FunctionsStrctured Programming Manual
QS001CPU Common InstructionsStrctured Programming Manual
QS001CPU FundamentalsStrctured Programming Manual
QS001CPU Multiple CPU SystemUser's Manual
QS001CPU Function Explanation, Program FundamentalsUser's Manual
QS001CPU Hardware Design, Maintenance and InspectionUser's Manual
QS001CPU Structured TextProgramming Manual
QS001CPU MELSAP-LProgramming Manual
QS001CPU SFCProgramming Manual
QS001CPU PID Control InstructionsProgramming Manual
QS001CPU Common Instructions 1/2Programming Manual
QS001CPU HardwareUser's Manual
QS001CPU Structured Text(ST)Programming Guide Book

MITSUBISHI QS001CPU Product information and technical parameters:
Brand: MITSUBISHI
Name: Secure CPU module
Model: QS001CPU
Control mode: loop program execution.
Input / output control mode: refresh mode.
Programming language: ladder diagram, function block.
Processing speed (CIS): 0.10 s.
Program capacity: 14k step.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down.

The input and output module installation number: 4.
Could extend the connection: not to extend the connection.
Application module: QS series module.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system QS001CPU.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards QS001CPU
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures QS001CPU.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down QS001CPU. "Transmission speed: 156kbps/625kbps/2.5Mbps/5Mbps/10Mbps (automatic tracking).
Station No.: 1~64 station.
External connection mode: 2 pieces of spring clip terminal.
Spring clip terminal.
The safety controller can communicate with the master station of the CCLINK system.
The data from the security controller to the master station can be edited by the parameters.
The security controller receives the data from the master station to set the tag name.
Transmission speed according to the automatic tracking station, do not need to set the transmission speed.
By using the spring clamping terminal, the wiring time and the maintenance time of the CC-Link cable can be reduced.
No need to re write parameters after replacement of the module.
The security controller can be set up and connected with the monitoring software.
Confirm the error record that is detected. Category: Category 4 (EN/ISO13849-1), class 4 (EN954-1).
Security level: SIL3.
Performance level: PLe.
PFHd:0.4E-091/h.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich sset of components can be easily and quickly set the hardware structure QS001CPU.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connecttion settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file QS001CPU.


...More relevant models >>>>