DC input, transistor (source) output.
Channel number: 2CH.
The signal level (phi A, Phi B): 2 ~ 5mA DC5/12/24V.
Pulse measurement function can be measured by measuring the pulse ON/OFF time and cycle, the length and speed of the workpiece.
For example, in the production of food, beverages, the use of proximity sensors to measure the size and speed of the bottle on the conveyor.
Operation control mode: stored procedure repeated operation.
Built in IE CC-Link.
Input / output points: 4096 points.
Program capacity: 40K.
Increase the speed of a constant cycle interrupt program.
Perform a minimum interval constant period interrupt program can be shortened to 50 s,
Programmable logic controller can read more high-speed signals RD62P2E.
In addition, the interrupt routine can be set priority, and the interrupt program with high priority is executed when the interrupt processing is interrupted
RD62P2E
Therefore, when the signal is read at a high speed, the program can read the signal from the constant cycle of the conventional input module +CPU module.
Soft element / label area for easy processing
The extended SRAM card is installed on the programmable controller CPU module,
Soft element / label storage area with up to 5786K words RD62P2E.
The expansion area is connected to the memory of the built-in CPU module,
The range of soft components / labels can be freely distributed.
Therefore, it can be easily programmed without taking into account the boundaries of each storage area.
In addition, can also use the SD memory card processing records data, database data, such as large capacity data RD62P2E. "Input points: 16 points.
Rated input voltage, frequency: AC100 ~ 120V, 50/60Hz.
Rated input current: 8.2mA (AC100V, 60Hz), 6.8mA (AC100V, 50Hz).
Response time: 20ms.
Common way: 16 point / public end.
Interrupt function: have.
External wiring connection mode: 18 point screw terminal.
The input and output module is the interface between the switch, sensor, actuator, and other control system of the ON/OFF signal processing.
Compared with the previous series, iQ-R MELSEC series of input and output modules have more features,
1 modules can be used for a variety of purposes, to help reduce the cost of deployment and maintenance costs.
The module design of the pursuit of convenience".
Paste the white label on the input module and paste the red label on the output module,
The rated specifications are clearly marked on the front of the module, which can prevent the use of errors.
The input and output number stamped on the top of the front display input and output module LEED, can easily confirm the status of the ON/OFF RD62P2E.
The terminal arrangement of each signal is recorded on the wiring terminal of the 16 point module, and the false wiring can be prevented.
The 64 point module can be 32 points as the unit, throough the switch to switch to display the input and output number RD62P2E.
In addition, serial number tag in the front of the module, can be easily recognized. "