Adapter kit (for CN3)RS-232C 1 channel, RS-422 1 channel.
Transfer speed: 0.3-19.2kbps.
Multi station communication network function (Master / local station).
How to determine the input / output device of MITSUBISHI plc.
According to the control requirements of the system,
All input devices and output devices required for the determination of the system,
To determine the input / output device related to the MITSUBISHI PLC,
To determine the I/O PLC points
AJ35PT-OPB-M1
Detailed analysis of the process and work characteristics of the controlled object,
To understand the coordination between the controlled object machine, electricity and liquid,
The control requirements of the controlled object for MITSUBISHI PLC control system are put forward,
Determine the control program, to develop a design task book. Max input / output points: 48 points.
Supply voltage: 100 - 240VAC.
Input points: 24 points.
Output points: 24 points.
Output type: Transistor (sinktype).
Power consumption: 40W.
Weight (kg):0.85.
Size (WxHxD) mm:182x90x86.
Faster and more efficient. Support high speed control and network communication, and have the function of data recording.
High speed, large capacity, multi-function high-end machine.
FX3U supports high speed processing, CC-Link communication, network communication, analog control and advanced positioning system.
Connected to the CC-Link, including the remote I/O, the maximum input and output control points up to 384 points,
Can correspond to a variety of field needs, the use of its scalability and flexibility to expand the scope of application of the control system.
Third generation high function micro programmable controller.
High speed, high efficiency, high performance, large capacity, and new features.
Built in high speed processing and positioning.
Control points: maximum 256 points.
Use CC-Link remote I/O for 384 points. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 11KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load.
AJ35PT-OPB-M1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=AJ35PT-OPB-M1&select=5