Memory format: RAM.
Number of steps: up to 16000 steps can be used.
Battery support: required.
Method for writing and deleting: the device is installed on the PLC, and is written and deleted by the peripheral device. Storage capacity: 32MB.
Applicable models: A985 (-V) /A975/A970/A960GOT (-B). Servo motor series: ultra low inertia, medium capacity.
Rated output: 1.0kw.
Rated speed: 3000r/min.
Electromagnetic brake: No
16KHROM
Power supply: 200V.
The most suitable medium capacity, ultra low inertia type product''s high frequency operation and so on.
Improve the environmental performance of HG-KR, HG-MR, HG-RR, HG-UR series of products using IP65.
100 scene, there are 100 different drive control.
In order to meet the needs of the diverse and detailed field,
MR-J4 product line configuration, providing a wealth of servo amplifier and servo motor products.
Can meet the different needs of different customers. Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 16A/ all points.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
All points of independence.
38 point terminal station.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points.
16KHROM Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=16KHROM&select=5