Type: HA-SH series.
Rated output: 2.0KW.
Rated speed: 2000r/min.
Electromagnetic brake: there.
From the vector control technology of AC servo motor, it has become more and more popular.
From the point of view of the real time operating system, it is just a function module that needs to be processed in real time.
Due to the multi function of the controller, intelligent requirements, a large number of signal processing,
Establishment and operation of various mathematical models of adaptive control,
Network communications and other functional modules will be in the real-time operation of the unified scheduling and management of the system to get the correct and reliable operation
AJ65BT-64RD4
Therefore, the next generation of servo drive controller will be a collection of various modern control technology of the crystallization,
Instead of the traditional sense of power amplifier.Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 16A/ all points.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
All points of independence.
38 point terminal station.
With the surge absorber.
CE certification.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points.
AJ65BT-64RD4 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=AJ65BT-64RD4&select=5