MITSUBISHI
Home >> Price >> MITSUBISHI >> MITSUBISHI FR-HAL-H560K Price
Brand sort

MITSUBISHI MITSUBISHI FR-HAL-H560K Price

Country: JAPAN
Name: AC reactor
Model: FR-HAL-H560K
Market price: U.S.$ 11791.53
(The following are the market open price not sales price!)
MITSUBISHI FR-HAL-H560K
Max input / output points: 16 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 8 points.
Output type: relay.
Power consumption: 30VA.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x87.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time FR-HAL-H560K
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program. 5 slots.
Requires 1 power modules.
Used to install the old section of the large A series PLC module.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
FR-HAL-H560K Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=FR-HAL-H560K&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
AC reactor
FR-HAL-H45K
MITSUBISHI AC reactor FR-HAL-H45K
Power: 45kw. Purpose: to suppress the po
MITSUBISHI
AC reactor
FR-HAL-H30K
MITSUBISHI AC reactor FR-HAL-H30K
Power: 30kw. Purpose: to suppress the po
MITSUBISHI
AC reactor
FR-HAL-H15K
MITSUBISHI AC reactor FR-HAL-H15K
Power: 15kw. Purpose: to suppress the po
MITSUBISHI
hpfr
FR-HC2-H560K
MITSUBISHI hpfr FR-HC2-H560K
Power: 560kw. Voltage: 400V. The power f