MITSUBISHI
Home >> Products >> MITSUBISHI >> Inverter >> Inverter accessories >> FR-HAL-H45K AC reactor

FR-HAL-H45K AC reactor

MITSUBISHI FR-HAL-H45K Manual And Instructions
FR-HAL-H45K datasheetPDF datasheet

MITSUBISHI FR-HAL-H45K Product information and technical parameters:
Brand: MITSUBISHI
Name: AC reactor
Model: FR-HAL-H45K
Power: 45kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.)

Voltage level: three phase 400V.
Applicable motor capacity: 450kw.
Substrate coating: have.
Built in DC reactor.
The operating frequency of the fixed alternating current is converted to DC power. MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 90kw.
SLD converter rated current: 475A FR-HAL-H45K.
Structure and function: Standard model.
Type: CA.
Substrate coating: have FR-HAL-H45K
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment) FR-HAL-H45K.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps FR-HAL-H45K. Length: 30 meters.
Cable manufacturing specifications.
When there is no connection options, according to the table under the cable.
Using a parallel connection or a large size cable for connection between the terminal PG" and "SD" and the motor end encoder. "Length: 1 meters.
Operation panel or parameter unit connection line. Superior high efficiency IPM motor.
Output power: 11kw.
Rated speed: 1500r/min.
Voltage level: 400V.
IPM motor MM-EFS series can not be used to run the power frequency power.
The total wiring length of the IPM motor shall not exceed 100m.
1 inverters can not connect multiple IPM motors at the same time. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 0.4kw.
SLD converter rated current: 4.6A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation.
(rectifier sseparation type will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station FR-HAL-H45K.
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same timme, used in the control of the external machine FR-HAL-H45K.
No external PID controller is used to control the external machine, so the system cost can be reduced.


...More relevant models >>>>