"Differential driver output.
Axis of control: 2.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Module backup function: the positioning data, module start data saved to the flash ROM (no battery).
Boot time (operation cycle 0.444ms, 1 axes): 0.3ms.
Maximum output pulse: 5000000 pulse/s.
The maximum distance between servo system: 10m.
External wiring connection: 40 pin connector two
MR-JHSCBL30M-L
Linear interpolation: 2 axes.
Arc interpolation: 2 axes.
Easy positioning control
The positioning module uses the position control and speed control, which is set by the engineering software.
In the position control and speed control is also equipped with an increase in the "conditional judgment" after the implementation of the specified positioning data and other advanced positioning control functions.
For example, in the automobile door sealing process, the need to carry out high precision positioning control,
In order to applying sealant on the sealing part of the door.
Therefore, it is necessary to track the precise trajectory through the straight line and the arc, and implement the high precision interpolation control.
Multiple start mode
In addition to the conventional positioning module startup, there are high-speed start, multi axis at the same time, such as the start of a variety of ways to start.
High speed start by analyzing the location data to be executed in advance,
High speed startup mode without data analysis time.
Multi axis simultaneous start up mode for starting output pulse at the same time that the object shaft is started simultaneously with the start of the shaft.
In addition, the module can be started to run according to a plurality of positioning data groups in turn at startup.
Can be used for repetitive control of the same locus. "For the QCPU (Q mode) / transport controller CPU (Q Series) bus connection (2 channel) unit standard model.
Applicable models: GT15, GT16, GT27, GT25. 10BASE5.
When communicating in the PLC network of MITSUBISHI,
There is no sense of difference and discontinuity in the network,
Can carry on the remote monitoring, modification, debugging and other work of data communication and program,
Without taking into account the level and type of network.
MELSECNET/H and CC-Link use the way of loop communication,
Periodically automatically send and receive messages,
Does not require specialized data communication procedures,
Simple parameters can be set.
MELSECNET/H and CC-Link are used to transmit and receive the broadcast mode,
This can be done on the network data sharing.
For the use of Ethernet, MELSECNET/H, CC-Link network,
Can set the network parameters and various functions, simple and convenient in the Developer GX software screen.
MR-JHSCBL30M-L Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MR-JHSCBL30M-L&select=5