MITSUBISHI
Home >> Products >> MITSUBISHI >> CC-Link module >> Location / interface / temperature module >> AJ65BT-68RD4 Temperature control module

AJ65BT-68RD4 Temperature control module

MITSUBISHI AJ65BT-68RD4 Manual And Instructions
AJ65BT-68RD4 datasheetPDF datasheet

MITSUBISHI AJ65BT-68RD4 Product information and technical parameters:
Brand: MITSUBISHI
Name: Temperature control module
Model: AJ65BT-68RD4
Screw, 2 piece type terminal
Platinum temperature measuring resistor body PT100 temperature input module.
Number of channels: 4 channels.
Number of stations: 4 stops.
Station type: remote equipment station.
MITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjust.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on step by step.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be.
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced.

Input type: DC input, positive public end / negative public end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
External connection: 3 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup AJ65BT-68RD4.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AJ65BT-68RD4 Input type: DC input, negative public end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA AJ65BT-68RD4.
External connection: 3 wire.
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/0 AJ65BT-68RD4. 1A.
External connection: 1 wire.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc. are connected to a simple MIL connector.
Simply remove the connector can be replaced with a simple module.
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space. Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/6mA.
External connection: 3 wire.
Spring clamping terminal platform push type input module.
Input module with diaggnostic function
The use of push type, do not need screw fastening, so can reduce the wiring hours AJ65BT-68RD4.
Can be used for each 1 points to enter the wiring of the broken wire detection.
Wiring abnormality of external power supply can be confiirmed AJ65BT-68RD4.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.


...More relevant models >>>>