Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module.
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.DC5V internal consumption current: 0.08A.
Weight: 0.12kg.
1 the field input interface module is composed of an optical coupling module and an input interface module of the microcomputer,
Function is the interface of the programmable logic controller and the field control FA-TB16XY1.
2 the field output interface module is integrated with the output data register, the gating module and the interrupt request module,
The programmable logic controller outputs the corresponding control signal to the execution part of the field through the field output interface module
FA-TB16XY1 Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output FA-TB16XY1. RS-232, RS-422/485.
Transmission speed: 230.4kbps.
MC protocol.
Communication protocol support function.
Can only be used on the ch1 side.
Device for immediate communication
Communication protocol support function through Works2 GX,
Can easily set the required agreement with the other equipment communication.
In addition, only the communication protocol library is required to select the equipment to be carried out,
Immediate connection FA-TB16XY1.
The creation and editing of communication protocols are simple and easy to implement, even if there is no connection equipment in the communication protocol library,
Can also simply create a corresponding protocol for communication.
The content of the communication protocol that can be created in the list,
Can also be simply edited. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output."Universal output function: leakage type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet (built-in CC-Link function).
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool FA-TB16XY1.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurrement FA-TB16XY1.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ". "