MITSUBISHI FA-TB8XY3 Manual And Instructions
FA-TB8XY3 datasheetPDF datasheet

MITSUBISHI FA-TB8XY3 Product information and technical parameters:
Brand: MITSUBISHI
Name: Conversion module
Model: FA-TB8XY3
Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module.

DC5V internal consumption current: 0.08A.
Weight: 0.13kg.
1 the field input interface module is composed of an optical coupling module and an input interface module of the microcomputer,
Function is the interface of the programmable logic controller and the field control.
2 the field output interface module is integrated with the output data register, the gating module and the interrupt request module,
The programmable logic controller outputs the corresponding control signal to the execution part of the field through the field output interface module FA-TB8XY3 FA-TB8XY3 Input power: DC24V.
Output: DC5V, 5A.
Power supply module can be directly pasted on the printed circuit board of the power supply,
The device is characterized in that a special integrated circuit (ASIC), a digital signal processor (DSP), a microprocessor, a memory, a field programmable gate array (FPGA), and other digital or analog loads are provided FA-TB8XY3.
In general, this type of module is called the load point (POL) power supply system or the use of point power supply system (PUPS).
Because of the advantages of the modular structure,
The module power supply is widely used in switching devices, access devices, mobile communications, microwave communications and optical transmission, routers and other communication fields and automotive electronics, aerospace, etc FA-TB8XY3. . Number of input channels: 4ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 40 s/2ch.
Resolution: 1/32000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth ccontinuous analog output FA-TB8XY3.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period FA-TB8XY3.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.