FA-TB32XYN3 Conversion module

MITSUBISHI FA-TB32XYN3 Manual And Instructions
FA-TB32XYN3 datasheetPDF datasheet

MITSUBISHI FA-TB32XYN3 Product information and technical parameters:
Brand: MITSUBISHI
Name: Conversion module
Model: FA-TB32XYN3
Convert connector to screw relay terminal.
2 wire connection, no need to use common terminal.
Positive common end use.

Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Number of input channels: 4ch.
Input voltage: DC - 10 - 10V.
Input current: DC0 ~ 20mA.
Input voltage: 100 ~ 100mV / minute.
Input thermocouple: K, J, T, E, N, R, S, B, U, L, PL II, W5Re/W26Re.
Input temperature resistance: Pt1000, Pt100, JPt100, Pt50 FA-TB32XYN3.
Conversion speed: 50ms/ch.
Resolution (voltage / current / micro voltage): 1/20000
Resolution (thermocouple): B, R, S, N, PL II, W5Re/W26Re:0 FA-TB32XYN33,, K, E, J, T, U, L:0.1.
Temperature measuring resistance: Pt100, JPt100:0.03, /0.1, Pt1000, Pt50:0.1.
Reduce the programming time.
The digital output value can be easily converted (zoom) to any number of functions without the program FA-TB32XYN3.
No need to use ladder diagram conversion program, can reduce the programming time.
Zoom setting example (L60AD4-CM).
The digital output value (20000 ~ 0) of the input range 20mA ~ 4mA is scaled to the value of positive and negative 20000.
Digital filter function
Simply set the parameters, you can eliminate the function of the redundant frequency components.
Can be selected from low pass filter, high pass filter, medium pass filter FA-TB32XYN3.
No need to filter the ladder, can reduce programming time.
In addition, the conversion value of the A/D converted by the filter can be obtained at the same time,
Therefore, the total processing time from the conversion to the filter processing can be shortened. Open collector output.
Axis of control: 2.
Maximum output pulse: pulse/s 200k.
Location data: 600 data / axis.
Max link distance: 2m.
With the parameter setting, the synchronization control can be easily realized. Do not need to write complex procedures.
Start / stop with synchronous control of the shaft.
Synchronous control of the axis and the positioning of the axis can coexist.
Through the clutch, the movement of the main shaft can be transferred to the output shaft.
Simple implementation of synchronization control.
Cam control is more simple
Cam data can easily create a variety of patterns.
Can be simple to achieve the gear, shaft, transmission, cam and other mechanical mechanisms to replace the software synchronization control.
It is not subject to the limitation of the concept of the electronic cam control so far, and can use the cam with high degree of freedom FA-TB32XYN3.
The stroke, speed, acceleration and beat can be confirmed on the graph, and the setting is carried out at the same timee FA-TB32XYN3.
Can also be through the cam data thumbnail display, easy to confirm the cam data has been created.
Can import and export the cam data in CSV format.