FA-TB32XYP3 Conversion module

MITSUBISHI FA-TB32XYP3 Manual And Instructions
FA-TB32XYP3 datasheetPDF datasheet

MITSUBISHI FA-TB32XYP3 Product information and technical parameters:
Brand: MITSUBISHI
Name: Conversion module
Model: FA-TB32XYP3
Convert connector to screw relay terminal.
2 wire connection, no need to use common terminal.
Negative common end use.

Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Input points: 8 points.
Rated input voltage: AC100 ~ 120V.
Common way: 8 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on FA-TB32XYP3 FA-TB32XYP3 FA-TB32XYP3 Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Positive common end use. Thermocouple input FA-TB32XYP3.
Number of input channels: 4ch.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode.
To achieve high stability temperature control
Standard control / heating, cooling control.
The device used for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling.
According to the object device can choose any one of the following control method.
Standard control (heating or cooling).
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control).
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time. To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity ccontract), and reduce the operation cost FA-TB32XYP3.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniiform, to ensure that the control object no local burning or thermal expansion FA-TB32XYP3.
No idle running, with energy saving effect, can reduce operating costs.