MITSUBISHI
Home >> Products >> MITSUBISHI >> L series PLC >> FA products >> FA-TH16X100D31L Terminal module

FA-TH16X100D31L Terminal module

MITSUBISHI FA-TH16X100D31L Manual And Instructions
FA-TH16X100D31L datasheetPDF datasheet

MITSUBISHI FA-TH16X100D31L Product information and technical parameters:
Brand: MITSUBISHI
Name: Terminal module
Model: FA-TH16X100D31L
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.

Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.DC5V internal consumption current: 0.08A.
Weight: 0.13kg.
1 the field input interface module is composed of an optical coupling module and an input interface module of the microcomputer,
Function is the interface of the programmable logic controller and the field control FA-TH16X100D31L.
2 the field output interface module is integrated with the output data register, the gating module and the interrupt request module,
The programmable logic controller outputs the corresponding control signal to the execution part of the field through the field output interface module FA-TH16X100D31L "Universal output function: leakage type FA-TH16X100D31L.
Program capacity: 20K step.
Basic operations processing speed: 40ns.
Communication interface: USB/Ethernet.
Control mode: stored procedure repeated operation.
Input / output points: 1024 points.
End cap.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement FA-TH16X100D31L.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ".
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting ddimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators FA-TH16X100D31L. "Convert connector to screw relay terminal.
2 wire connection, no need too use common terminal FA-TH16X100D31L.
Negative common end use. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.