MITSUBISHI
Home >> Products >> MITSUBISHI >> Inverter >> FR-A700 series inverter >> FR-A740 inverter 3 phase 400V >> FR-A740-185K-CHT 3 phase 400V converter

FR-A740-185K-CHT 3 phase 400V converter

MITSUBISHI FR-A740-185K-CHT Manual And Instructions
FR-A740-185K-CHT datasheetPDF datasheet
FR-A740-185K-CHT PLC FUNCTION PROGRAMMING MANUAL
FR-A740-185K-CHT BASICINSTRUCTION MANUAL
FR-A740-185K-CHT AppliedINSTRUCTION MANUAL
FR-A740-185K-CHT TECHNICAL MANUAL

MITSUBISHI FR-A740-185K-CHT Product information and technical parameters:
Brand: MITSUBISHI
Name: 3 phase 400V converter
Model: FR-A740-185K-CHT
MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 185KW.
Frequency converter is the application of frequency conversion technology and micro electronics technology, by changing the motor operating power frequency mode to control the AC motor power control equipment.
The converter is composed of rectifier (AC), filter, inverter (DC), braking unit, driving unit, micro processing unit of the detection unit.
Inverter by the internal IGBT to adjust the output power supply voltage and frequency,
According to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition to the,
Inverter has a lot of protection functions, such as over current, over voltage, overload protection and so on.

Power: 22kw.
Voltage: 200V.
The surge voltage of the motor can be suppressed when the 400V motor is driven by a frequency converter.
Motor suitable for 5.5 to 37kW. Power: 37kw.
Voltage: 200V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control FR-A740-185K-CHT.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost FR-A740-185K-CHT
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving. Length: 1 meters.
Operation panel or parameter unit connection line. "Power: 15kw.
Voltage: 200V FR-A740-185K-CHT.
Brake resistor, a kind of ripple resistance, is mainly used in the mechanical system of the inverter to control the speed of the motor,
Help the motor to be converted into heat energy due to the regenerative power of the motor.
Braking unit principle: the brake unit is composed of a high power transistor GTR and its driving circuit.
Its function is to link the discharge current braking resistor capacitor voltage or not in the range of the time consumed and the DC part "overpressure",
Need to add external braking components, in order to speed up the speed of the consumption of renewable energy FR-A740-185K-CHT. "Power: 45kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 630KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
Why is the frequency of the inverter voltage proportionaal to the change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the mmotor FR-A740-185K-CHT FR-A740-185K-CHT.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity.


...More relevant models >>>>