MITSUBISHI
Home >> Products >> MITSUBISHI >> Inverter >> IS70 series inverter >> IS74-2.2K-CHT Three phase 400V level inverter

IS74-2.2K-CHT Three phase 400V level inverter


MITSUBISHI IS74-2.2K-CHT Product information and technical parameters:
Brand: MITSUBISHI
Name: Three phase 400V level inverter
Model: IS74-2.2K-CHT
Applicable motor capacity: 2.2KW.
Rated current: 1.2A.
Power supply voltage: three phase 400V.
Frequency converter and GOT supporting the use, to achieve a higher price.
SIMPLE GOT series can be directly connected to the IS70 series inverter.
GOT can be directly connected with the inverter. After connecting the two, the communication parameters can be automatically set.
In addition, the software can display the soft component of the control function in the GOT, even when the multi frequency converter is connected,
Can also be unified management with 1 GOT.
Through the GOT screen to create software to import the picture data after the GOT,
Only use RS-422 connection GOT and frequency converter,
Can change the inverter speed / direction, monitoring the output frequency / output current and set a variety of parameters.

Length: 5 meters.
Cable manufacturing specifications.
When there is no connection options, according to the table under the cable.
Using a parallel connection or a large size cable for connection between the terminal PG" and "SD" and the motor end encoder. "MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V IS74-2.2K-CHT.
Power: 7.5kw.
SLD converter rated current: 49A.
Structure and function: Standard model IS74-2.2K-CHT
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment) IS74-2.2K-CHT.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps IS74-2.2K-CHT. Length: 15 meters.
Cable manufacturing specifications.
When there is no connection options, according to the table under the cable.
Using a parallel connection or a large size cable for connection between the terminal PG" and "SD" and the motor end encoder. ""MITSUBISHI inverter FR-F720P series.
Voltage level: three phase 200V.
Frequency converter capacity: 18.5KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, whiich is mainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply IS74-2.2K-CHT.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter IS74-2.2K-CHT. "


...More relevant models >>>>