MITSUBISHI
Home >> Products >> MITSUBISHI >> L series PLC >> CPU and accessories >> CPU >> L02SCPU-CM cpu module

L02SCPU-CM cpu module

MITSUBISHI L02SCPU-CM Manual And Instructions
L02SCPU-CM datasheetPDF datasheet
L02SCPU-CM Common InstructionsProgramming Manual
L02SCPU-CM Special InstructionsProgramming Manual
L02SCPU-CM Application FunctionsProgramming Manual
L02SCPU-CM Common InstructionsProgramming Manual
L02SCPU-CM Structured Text(ST)PROGRAMMING Guide Book
L02SCPU-CM Structured TextProgramming Manual
L02SCPU-CM MELSAP-LProgramming Manual
L02SCPU-CM Structured TextProgramming Guide
L02SCPU-CM PID Control InstructionsProgramming Manual
L02SCPU-CM Special InstructionsProgramming Manual
L02SCPU-CM Common InstructionsProgramming Manual
L02SCPU-CM Application FunctionsProgramming Manual
L02SCPU-CM ApplicationUser's Manual
L02SCPU-CM Structured TextProgramming Manual

MITSUBISHI L02SCPU-CM Product information and technical parameters:
Brand: MITSUBISHI
Name: cpu module
Model: L02SCPU-CM
"Universal output function: leakage type.
Program capacity: 20K step.
Basic operations processing speed: 60ns.
Communication interface: USB/RS-232.
Control mode: stored procedure repeated operation.
Input / output points: 1024 points.
End cap.
Unable to install display module (L6DSPU-C-CM), RS-232 adapter, RS-422/485 adapter.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ".
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators. "

Differential output.
Axis of control: 2.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start L02SCPU-CM.
The use of steps in accordance with the auxiliary function can be L02SCPU-CM
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, bit 8CH data can be displayed in real time.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check L02SCPU-CM.
Can only choose the necessary items from the rich monitoring information and monitor the display.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action. "Universal output function: leakage type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet (built-in CC-Link function) L02SCPU-CM.
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool L02SCPU-CM.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurrement L02SCPU-CM.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ". "


...More relevant models >>>>