MITSUBISHI
Home >> Products >> MITSUBISHI >> L series PLC >> CPU and accessories >> CPU >> L26CPU-BT-CM cpu module

L26CPU-BT-CM cpu module

MITSUBISHI L26CPU-BT-CM Manual And Instructions
L26CPU-BT-CM datasheetPDF datasheet
L26CPU-BT-CM Common InstructionsProgramming Manual
L26CPU-BT-CM Special InstructionsProgramming Manual
L26CPU-BT-CM Application FunctionsProgramming Manual
L26CPU-BT-CM Common InstructionsProgramming Manual
L26CPU-BT-CM Structured Text(ST)PROGRAMMING Guide Book
L26CPU-BT-CM Structured TextProgramming Manual
L26CPU-BT-CM MELSAP-LProgramming Manual
L26CPU-BT-CM Structured TextProgramming Guide
L26CPU-BT-CM PID Control InstructionsProgramming Manual
L26CPU-BT-CM Special InstructionsProgramming Manual
L26CPU-BT-CM Common InstructionsProgramming Manual
L26CPU-BT-CM Application FunctionsProgramming Manual
L26CPU-BT-CM ApplicationUser's Manual
L26CPU-BT-CM Structured TextProgramming Manual

MITSUBISHI L26CPU-BT-CM Product information and technical parameters:
Brand: MITSUBISHI
Name: cpu module
Model: L26CPU-BT-CM
"Universal output function: leakage type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet (built-in CC-Link function).
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ". "

Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Number of input channels: 8ch.
Input current: DC0 ~ 20mA.
Conversion speed: 1ms/ch.
Resolution: 1/8000.
By shifting the function easily when the system starts to fine tune the movement function.
Shift the set value to (shift to) the function of the digital output value L26CPU-BT-CM.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup L26CPU-BT-CM
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal detection function of the input signal which is outside the range of the set range L26CPU-BT-CM.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter range extension
Range of scalable input range.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected L26CPU-BT-CM. Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.DB A20 AnyWire master station.
Transmission distance: the longest 3km.
Data input and output: up to 1024 points.
Connect up to 128 units.
Enter 512 points, 512 points out of the output.
Support environmental protection, high speed, long distance transmission and special distribution system to support the special flat cable, universal VCTF cable, universal single wire cable and other cable.
Using original transmission mode, there is almost no branch limit,
Supports the automatic track and ring transmission,
Can also create suitable for small and medium sized factory wiring system.
Support remote I/O, analog quuantity, temperature and humidity terminal, anti false operation terminal and other equipment L26CPU-BT-CM.
Up to 128 units from the station module
Can connect up to 128 units from the station module, for up to 1024 points (input 512 points / outputt 512 points) of the I/O control L26CPU-BT-CM.
In addition, the parameters can be set through the switch, easy to set the transmission distance of 50m/200m/1km/3km.